Current OTM Patches
Nortel has released 21056su1, a
comprehensive patch for OTM version 2.10.56 that is
considered the minimum patch level for this version
going forward. Below is a listing of items fixed by
this patch. Patches are also available for OTM versions
2.00.50 and 2.01.37. Per Nortel, OTM version 2.2 is
scheduled to be released later this Fall.
Q00773522 Report Generator missing
values assigned to AST feature
Q00597841 Traffic data collection task
launched from the scheduler hangs
Q00626491 Product improvement on OTM-DECT
Serviceability DECT Performance
Q00716112 Unable to synchronize attributes
between OTM and Novell NDS
Q00738608 Transmission of RPL records
incomplete if one set gets SCH
Q00743504 The scheduled task on French/German
end userpage is not executed on time
Q00745767 Maintenance Windows PE Units
displays Status with TBUG613
Q00746169 Display wrong number of Intrazone
call made in Intrazone etherset data report
Q00746432 Retrieving PCA set in OTM
does not fill in the HOT_P key information
Q00746847 DN not updated in Employee
Editor if set has DN configured on key1 or above after
a parse
Q00757720 Cannot change language in
CPND Name
Q00758289 OTM does not NULL Key 27
or Key 28
Q00758289-01 SCH1370 on keys 27 and
28 when running x11 25.30
Q00764449 Traffic data collection/parsing
task launched from the scheduler
Q00765138 System Terminal configuration
problem on Branch Office
Q00773522 Report Generator missing
Values assigned to AST Feature
Q00789147 SCH1206 when we tried to
RPL the set
Q00797489 OTM Traffic Processor Load
Report:Hour of MaxRTUvalue not available above Rls 24
Q00800351 Cannot perform LDAP synch
with Windows Server 2003 Active Directory
Q00812495 Remove the DECT's dependency
on VeriSign certification.
Q00813988 Unable to Merge previous
release of Traffic Db to OTM 2.10.56
Q00821980 PUA feature does not work
when Machine type is Succession
Q00832217 Maintenance mode
auto sync dialog not popped for cpnd changes
Q00836589-04 Changing SNMP Community
String Names does not prevent access using default names
Q00836777 Scheduler hangs when traffic
parsing
Q00839332 Modem is not disconnected
when the parse begins
Q00843522 Wrong site accessed when
using VT220 from OTM
Q00845632 Cannot change CLS from TDD
to ADD
Q00857365 Scheduled Jobs to PBX fail
after upgrade to 2.10.56
Q00879139 LDAP sync doesn't show correct
Danish characters for Active Directory
In addition to the above, there is also a correction
to the Traffic module with Q00813988. Previously, the
software was unable to merge Traffic data from a previous
release into the OTM 2.10.56 Traffic database. The patch
includes a utility that allows you to convert prior
OTM Traffic archives into 2.10.56 format.
After installing the 21056su1 patch, go to the main
Traffic window and click on the Maintenance
menu and open the Traffic Database
to view the Database Maintenance screen
as seen in Figure 1. Then click on
File and proceed to Update
Archive. As shown in Figure 2, use
the first box to designate the OTM version of the older,
saved Traffic archive file. The example shows 2.00.50.
Then use the second box to select the location of the
older archived file. In the third box, provide a new
location and file name for the updated archive file.
Then click the OK button.
When the process has completed, you will be able to
restore the newly archived file into the 2.10.56 Traffic
database. Simply, return to the Database Maintenance
screen, click on File and go to Merge.
This is shown in Figure 3. Enter the
location of the new file in the Source box as shown
in Figure 4, and click the OK button.
You will now be able to run reports on older data without
corruption.